P&K 3783



Source data for the dispersion calculation according to VDI 3783
Burst pipe on the roof 12.12.91

Input for the dispersion calculation according VDI 3783 part 1
Ambient development height [m] 0
Source height [m] 10
X-Expansion of the source [m] 0
Y-Expansion of the source [m] 0
Z-Expansion of the source [m] 0
Inversion for mean situation? no
Dispersion category stable
Wind velocity [m/s] 2
Consider rise? no
Threshold for rise [MW] 6
Roughness category individual buildings/trees
Number of supporting points for the calculation 0
Calculate the worst values? yes
Calculate ambient air course? yes

Input for dispersion calculation according to VDI 3782 part 2
Dispersion area area I
Type of release gaseous

Material list
Name Density T-equivalent Conc.
  [kg/m³] [°C] [g/m³]
BENZENE 3.4900 -171.7 120
PROPANE 2.0100 -97.17 34
ACETONE 2.5900 -136.5 100
METHANE 0.7200 217.86 122

Parameter for VDI 3783 part 2
Name Boiling point Lower flammability limit Part 2 Flammability distance [m] LC
  [°C] [%]   mean worst [m]
BENZENE 80.20 1.200 continuous 87.95 114.7 0.412
PROPANE -42.1 2.100 continuous 52.66 82.07 0.391
ACETONE 56.30 2.5 continuous 58.25 89.33 0.481
METHANE -162 5 not required 0 0 0

Emission course
Duration Exhaust volume rate Temperature Heat
[s] [m³/s] [°C] [MW]
50 12 200 2.8044
150 2 30 0.0492
70 5 50 0.2460